Quick Answer: How to reset EcoWater softener controls depends on what you see. A flashing time after a power outage only needs the clock set: press SELECT until PRESENT TIME shows, adjust with UP/DOWN, then press SELECT. An Err code needs the power supply unplugged, the fault fixed, the plug put back and at least 8 minutes of waiting. Hard water after running out of salt needs a recharge (hold RECHARGE). Save the full factory reset (hold SELECT until CODE appears, press UP until SoS flashes, press SELECT) for scrambled settings, because it erases hardness and recharge time.
If you're searching for how to reset EcoWater softener controls, you probably have one of four problems, and each one has its own fix. The factory reset is the one people reach for first and the one that causes the most trouble afterward, because it wipes your hardness number and recharge time. A softener running on factory defaults may regenerate far too often or not often enough for your water. So match the symptom first, then use the smallest reset that solves it.
The steps below come from EcoWater's owner's manual for the EEC 1502R25 and EEC 1502R40 demand-initiated softeners (document 7349023), hosted by an EcoWater dealer here. Many EcoWater and dealer-branded models with the four-button UP / DOWN / RECHARGE / SELECT keypad work the same way. Wi-Fi models, color touchscreens and older dial timers use different menus, so if your keypad doesn't match, find the model number on the label and download that manual.
In this guide
- Match the symptom to the right reset
- A flashing clock after a power outage
- How to clear an EcoWater Err code
- Force a recharge when the water turns hard
- The SoS factory reset, step by step
- How to reset EcoWater softener settings after a wipe
- The hidden diagnostic screen
- FAQ
- Use the smallest reset that fixes the problem
Match the symptom to the right reset
| What you see | What to do | Settings lost? |
|---|---|---|
| Time flashing, everything else normal | Reset the clock | No |
| Err01, Err03, Err04 or Err05 | Unplug, fix the cause, plug in, wait 8 minutes | No |
| Hard water after the salt ran out, or after service | Refill salt, then force a recharge | No |
| Wrong settings, wrong model code, erratic behavior | SoS factory reset | Yes, all of them |
| Blank display | Check power first (below) | No |
Three of the four resets leave your settings alone. Only the SoS reset starts the controller from scratch, which is why it belongs at the bottom of the list.
A flashing clock after a power outage

This is the most common "reset," and it's barely one. According to the manual, internal memory keeps most settings, including hardness and recharge time, through an outage. Unless the outage was very brief, though, the present time is lost. While the power is off the display is blank and the softener won't recharge. If it was in the middle of a recharge when power dropped, it finishes that cycle when power returns.
When the power comes back, look at the display:
- Steady time: the clock survived. Nothing to do.
- Flashing time: the clock needs setting. If you skip it, recharges will most likely happen at the wrong hour, like mid-afternoon while the washer is running.
To set it:
- Press SELECT until PRESENT TIME shows. After an outage, 12:00 PM flashes.
- Use UP or DOWN to set the time. A quick tap moves one step; holding the button scrolls fast. Check the AM/PM indicator.
- Press SELECT. The display moves to HARDNESS. Confirm the number is still yours and press SELECT again.
- You'll land on RECHARGE TIME (default 2:00 AM, adjustable in 1-hour steps). Press SELECT once more to return to the normal time display.
If you leave any setting screen untouched for 4 minutes, the control drops back to the time display on its own, so don't worry about getting stuck halfway. The same steps handle daylight saving time; our daylight saving time guide explains when a one-hour drift matters.
EcoWater's UK site says its softeners keep their memory through a power cut and that after an outage of more than 72 hours only the time needs resetting. The US EEC 1502 manual says much the same in its own words: settings survive, the clock may not. Check the clock and leave everything else alone.
If the display is completely blank

A blank screen isn't a reset problem. The control runs on 24V DC from a plug-in power supply that needs a 120V outlet nearby. Work through it in this order:
- Confirm the outlet has power by plugging in a lamp or phone charger.
- Check the breaker, and reset any GFCI outlet that shares the circuit.
- Make sure the power supply's cord is seated at the control board end, not just at the wall.
- Look at the power supply itself for damage. The manual says to use only the included supply and to keep the outlet and supply indoors, out of wet weather.
If the outlet is live and the display stays dark with the original supply plugged in, the supply or the control board is the suspect, and that's a parts question rather than a reset.
How to clear an EcoWater Err code

When an Err code is on the screen, every button except SELECT stops working. That's deliberate: SELECT stays live so a service tech can get into the diagnostic screen. The manual lists four codes:
| Code | Parts the manual points to |
|---|---|
| Err01 | Motor, valve position switch |
| Err03 | Motor, valve position switch, wire harness |
| Err04 | Valve position switch |
| Err05 | Electronic control board |
To clear one:
- Unplug the power supply from the outlet.
- Correct the problem. Check the harness plugs at the board and motor, and look for anything binding the valve cam.
- Plug the power supply back in.
- Wait at least 8 minutes while the control moves the valve through a full cycle. If the code returns, the problem wasn't fixed.
Unplugging and replugging without step 2 can make the code vanish for a while, but it comes back the next time the valve has to move. Our EcoWater error codes guide covers what each code points to and which repairs are realistic at home.
Force a recharge when the water turns hard
Nothing is wrong with the control here. The resin is exhausted, usually because the salt ran out or a salt bridge stopped brine from forming. Refill the salt, give it a couple of hours to make brine, then start a recharge:
- Recharge now: press and hold RECHARGE for a few seconds until RECHARGE NOW flashes. You'll hear the valve motor start. Once it starts it can't be canceled, and during the recharge hard water is bypassed to the house, so avoid running hot water or the water heater refills with hard water.
- Recharge tonight: tap RECHARGE without holding it. RECHARGE TONIGHT flashes and the softener recharges at the set time. Tap RECHARGE again to cancel before it starts.
If the softener has been without salt for a long stretch, one recharge may not fully restore it. Running a second one the next night is reasonable.
Coming back from bypass after a repair
If you had the softener in bypass for a repair, the manual's start-up sequence is worth borrowing: start a recharge, and once the valve is in backwash, move the bypass back to service slowly, pausing several times so the tank pressurizes gently. Snapping it open drives air through the system. If pressure is weak afterward, see our guide to no water pressure after bypass. After a long idle period, consider sanitizing the softener before you put it back in service.
The SoS factory reset, step by step

The SoS reset returns the electronic controller to its factory defaults for every setting. Use it when the settings are scrambled, someone changed the model code, or the control is behaving erratically and the steps above didn't help. Before you start, write down your hardness number and recharge time.
- Press and hold SELECT until the display changes twice and shows CODE with a flashing model code. On the EEC 1502 models that should read EC25 (R25) or EC40 (R40).
- Press UP, a few times if needed, until SoS flashes.
- Press SELECT. The controller restarts.
- Set the present time, hardness and recharge time again, as in the clock section above.
Don't change the model code while you're on that screen unless it's wrong. The code tells the control what size resin bed it's running, and the manual warns that a wrong code means the softener operates on incorrect configuration data. If you do change it, every controller setting has to be entered again afterward.
How to reset EcoWater softener settings after a wipe

After an SoS reset, the softener knows nothing about your water. Put these back before you walk away:
- Hardness, in grains per gallon. If you have clear-water (ferrous) iron, the manual says to add 5 to the hardness number for each 1 ppm of iron. Its example: 20 gpg hardness with 2 ppm iron is entered as 30.
- Potassium chloride users: the manual says to raise the hardness setting by 25% if you use potassium chloride instead of sodium chloride salt.
- Recharge time: 2:00 AM is the default and suits most homes, because nobody is using water. Pick a time when the house is quiet.
- Salt efficiency (optional): this feature ships OFF. When it's ON, the softener recharges more often with smaller salt doses. The manual says it must be turned on for installations in California.
If you don't have a recent hardness number, test before you guess. A drop-count kit is more precise than strips, and our picks for the best water hardness test kits include both. The walkthrough on how to set hardness on a softener explains why a number set far too high just wastes salt and water.
The hidden diagnostic screen

Before you call for service, a few minutes in the diagnostic screen tells you a lot. Remove the two screws holding the faceplate and lift it so you can watch the cam. Then press and hold SELECT for 3 seconds:
- "000 – -" means the position switch is open (valve parked in a position). "000 – P" means it's closed (valve moving).
- The first three digits should count up whenever water flows. If they don't move with a faucet open, the meter isn't reading, and a demand softener that can't count water will never call for a recharge.
- UP shows how many days the control has had power. DOWN shows how many recharges it has started since the model code was entered.
- RECHARGE steps the valve through each position so you can confirm the switch responds.
The display returns to normal after 4 minutes without a button press. Note what you saw; it shortens a service call.
FAQ
Does unplugging an EcoWater softener reset it?
Unplugging doesn't erase your settings. The control keeps hardness and recharge time in memory, though you may have to set the clock again. Unplugging is also step one of clearing an Err code, but it only works if you fix the fault before plugging back in.
How do I reset my EcoWater softener after a power outage?
Look at the display when power returns. If the time is steady, do nothing. If it's flashing, press SELECT until PRESENT TIME shows, set the time with UP and DOWN, then press SELECT through HARDNESS and RECHARGE TIME to get back to the normal display.
What does SoS mean on an EcoWater softener?
SoS is the factory reset option on the CODE screen. Selecting it restarts the electronic controller with factory defaults for all settings, so you must enter the time, hardness and recharge time again afterward.
How do I make my EcoWater softener regenerate right now?
Press and hold RECHARGE for a few seconds until RECHARGE NOW flashes. The recharge starts at once and can't be canceled. A short tap instead sets RECHARGE TONIGHT, which runs at the scheduled recharge time.
Why does my EcoWater softener keep showing the same Err code?
The fault is still there. Err01 and Err03 point to the motor, valve position switch or wiring, Err04 to the position switch, and Err05 to the control board. Clearing the code without fixing the part just brings it back on the next valve move.
Use the smallest reset that fixes the problem
Most of the time, how to reset EcoWater softener controls comes down to setting a flashing clock or forcing one recharge after the salt ran out. Clear Err codes only after fixing what caused them, and keep the SoS factory reset for genuinely scrambled settings, with your hardness and recharge time written down first. If you find yourself resetting every few weeks, the cause is usually hardware: a failing position switch, a tired motor, or an unreliable outlet. Older units with repeated control faults are often where people start comparing options, and our EcoWater vs RainSoft comparison covers how those two dealer brands differ on service and long-term cost. For the bigger picture of how a softener uses salt and water during regeneration, Penn State Extension's water softening guide is a good, brand-neutral read.