Rheem Water Softener Error Codes: What E1 to E5 and 01 to 09 Mean, and How to Clear Them

Quick Answer: Rheem water softener error codes point to the valve's electrical system. E1, E3 or E4 mean a fault in the position switch wiring, the switch itself, a stiff valve (rotor and seal) or the motor. E5 means the electronic control board has failed. On the Wi-Fi RHW42, codes 07, 08 and 09 are about the optional water shutoff valve. To clear any of them, unplug the power supply, fix what you can, plug it back in and wait 8 minutes.

The display has swapped the time of day for a flashing "Err" and a code, and every button except SELECT has stopped working. That's by design: Rheem locks the keypad while an error shows so a service tech, or you, can get into diagnostics. Everything below comes from Rheem's own installation and operation manuals for the RHS32 (Preferred), RHS42 (Preferred Plus) and RHW42 (Preferred Platinum). The manuals name Water Channel Partners as the manufacturer.

In this guide
  1. Rheem water softener error codes at a glance
  2. E1, E3 or E4: motor, cam and position switch
  3. E5: the control board itself
  4. Codes 07, 08 and 09 on the Preferred Platinum (RHW42)
  5. Clear the code with the 8-minute test
  6. Find the fault with Manual Advance Diagnostics
  7. No code, but the water is still hard
  8. FAQ
  9. Fix the switch side first, the board last

Rheem water softener error codes at a glance

Diagram of which Rheem water softener error codes appear on the RHS32, RHS42 and RHW42

Check the model sticker inside the salt lid first, because the Wi-Fi model adds codes the others don't have.

CodeModelsWhat the manual saysFix
E1, E3, E4RHS32, RHS42, RHW42Fault in the wiring or connections to the position switch, a bad switch, a valve fault causing high torque, or a dead motorReseat or replace the harness, then switch, rotor/seal or motor
E5RHS32, RHS42, RHW42Electronic control malfunctionReplace the control board
01 to 05RHW42Softener faults not related to the shutoff valveUnplug, correct, plug in, wait 8 minutes
07, 08, 09RHW42Problem with the optional motorized water shutoff valveCheck it's plugged in, hold RECHARGE 3 seconds

A flashing status light with "Err" on the screen means the self-diagnostics found a problem. The self-check covers the electrical system only. Per the RHS32 manual, it does not check input power or the water meter, so a dead meter or a plugged brine line shows up as hard water, not as a code.

E1, E3 or E4: motor, cam and position switch

Diagram of the Rheem valve drive: motor, cam and position switch, with the four causes of E1, E3 and E4

The control turns a motor that rotates the valve through each recharge stage, and a position switch riding on a cam tells the board where the valve is. These three codes mean the board didn't see the switch change when it expected to. The manual lists the causes in this order:

  1. Wiring or connections to the position switch. The cheapest fix and the first to check. Unplug the power, lift the top cover and make sure the motor and switch plugs are fully seated.
  2. A failed switch. Replace the switch.
  3. A valve fault causing high torque. Worn or swollen rotor and seals make the motor work too hard. Replace the rotor and seal.
  4. A motor that won't run. Replace the motor.

The same table lists "motor stalled or clicking" as its own symptom, caused by a motor fault or high torque from the valve. If the motor won't turn at all with power present, our guide to a water softener motor that isn't turning walks through checks that apply here too.

E5: the control board itself

Close-up of an electronic control board, the part a Rheem water softener E5 error code points to

E5 is the one code with a single answer in every Rheem manual: an electronic control malfunction, fixed by replacing the control board. Before buying one, unplug the unit for a full minute and run the 8-minute test below. If E5 returns, call Rheem with the model and serial number from the rating decal inside the salt lid. A board on an older unit can cost enough that our repair-or-replace guide is worth a look first.

Codes 07, 08 and 09 on the Preferred Platinum (RHW42)

The Wi-Fi RHW42 can drive an optional motorized water shutoff valve, and it numbers its codes differently. Codes 01 through 05 are softener faults, cleared with the same unplug-and-wait procedure. Codes 07, 08 and 09 mean a problem with the shutoff valve. The manual's fix:

  • Make sure the shutoff valve is still plugged into the softener's control board.
  • Press and hold RECHARGE for 3 seconds to clear the code.
  • If the code comes back after a minute or two, the shutoff valve probably needs replacing.

On the RHW42, a status light that's off while the display still works can also mean the unit lost its Wi-Fi connection to the cloud, not a fault.

Clear the code with the 8-minute test

Four-step diagram of the Rheem error clearing procedure ending with an 8-minute wait

For E1 to E5 (and 01 to 05 on the RHW42), the manual's procedure is:

  1. Unplug the power supply from the outlet.
  2. Correct the problem if you can see it: a loose plug, a cover not seated, something wedged near the cam.
  3. Plug the power supply back in.
  4. Wait 8 minutes. If the fault is still there, the code returns.

Don't skip the wait. A normal clock for the first minute doesn't mean it's fixed; the controller needs that time to recheck the valve.

Find the fault with Manual Advance Diagnostics

Diagram of the Rheem diagnostic screen: meter digits, P or dash for the position switch, and the button functions

When the code keeps coming back, the diagnostic screen lets you watch the valve move through a recharge.

  1. Lift the salt lid and remove the top cover (on the RHS32, unlock the tabs at the back and rock it forward) so you can see the cam and switch.
  2. Press and hold SELECT for 3 seconds until 000 shows, then release.
  3. Meter digits: with no soft water running they stay at 000. Open a soft-water faucet and they should count up once per gallon (000 to 199 on the RHS32, 000 to 140 on the 42 models). No movement with water flowing means the meter isn't reporting.
  4. Position switch: a P means the switch is closed; a dash means it's open. It should change as the cam turns.
  5. Press RECHARGE to step the valve into each cycle. A motor that hums without turning the cam, or a cam that turns while the P never changes, is your fault.

While in that screen, UP shows days the control has had power and DOWN shows recharges started. Months of power with very few recharges means it hasn't been regenerating properly. Hold SELECT until the model code shows (rH32 or rH42); a wrong code means wrong configuration data, so correct it with UP or DOWN.

Reset to factory defaults

A last resort, since it wipes time, hardness and every other setting. Hold SELECT until the display changes twice and the model code flashes, press UP until SoS flashes, then press SELECT. The controller restarts and you re-enter your settings. Afterward, hold RECHARGE for 3 seconds for RECHARGE NOW, which takes about 2 hours, and test a soft-water tap.

No code, but the water is still hard

Checklist diagram of Rheem no-code hard water causes: salt, bridge, bypass, nozzle and venturi, drain hose and settings

Because the self-check ignores the meter and the brine side, many Rheem problems never trigger a code. The manual's troubleshooting table points to:

  • No salt or a salt bridge. Refill, or break the crust; see our guide to a water softener salt bridge.
  • Bypass valve left in bypass.
  • Dirty or unseated nozzle and venturi. The most likely reason for no brine draw; see how to clean a water softener injector.
  • A restricted drain hose. The manual says to avoid runs longer than 30 feet or raised more than 8 feet above the floor, especially with low water pressure.
  • Wrong time, hardness or model code, or hot water used during a recharge.
  • Low or high pressure. At least 20 psi; add a pressure reducing valve if daytime pressure tops 100 psi.

If you suspect the tubing, see how to clear a clogged brine line. For other brands and blank screens, our error code and blank display guide covers power problems too. Rheem's owner resources page links current manuals and support.

FAQ

What does E1 mean on a Rheem water softener?

E1, like E3 and E4, means the control didn't see the position switch respond as the valve turned. The manual's causes, in order: loose or faulty wiring to the switch, a failed switch, a stiff valve (rotor and seal) or a motor that won't run.

How do I reset Rheem water softener error codes?

Unplug the power supply, correct the problem, plug it back in and wait 8 minutes. If the code returns, the fault is still there. RHW42 codes 07 to 09 clear by holding RECHARGE for 3 seconds.

What does E5 mean on a Rheem softener?

An electronic control malfunction. The manual's fix is a new control board, but try the 8-minute unplug test first.

Why are all the buttons locked on my Rheem softener?

While an error code shows, every button except SELECT is disabled. SELECT stays active so you can enter Manual Advance Diagnostics.

How do I factory reset a Rheem water softener?

Hold SELECT until the model code flashes, press UP until SoS flashes, then press SELECT. You'll need to re-enter the time, hardness and other settings.

Fix the switch side first, the board last

Most Rheem water softener error codes trace to the valve drive, not the brain. Start with the cheap end of the manual's list: reseat the plugs, run the 8-minute test, and watch the cam and P indicator in diagnostics before buying a switch, rotor, motor or board. Only E5 points straight to the control board. If you do end up replacing the whole unit, our Rheem vs Whirlpool comparison and best 48,000-grain softeners are good next reads.