Fleck 5600SXT Error Codes (Err 0, 1, 2, 3 and UD)

Quick Answer: Fleck 5600SXT error codes come in five types. Err 2 (Regen Failure) is the common one: hold Extra Cycle for 5 seconds to start a manual regeneration, which clears it, then find out why it stopped regenerating. Err 0 (Cam Sense) means the valve took over 6 minutes to reach its next position. Err 1 is an unexpected switch signal. Err 3 needs a Master Reset and reprogramming. UD clears itself.

The codes appear on the normal In Service screen, and they're short and well documented. Everything below comes from the error code table in Pentair's 5600SXT Softener System manual (document 4005293), which covers the control sold on Pentair's 5600SXT softener series.

In this guide
  1. Fleck 5600SXT error codes at a glance
  2. Err 2 means 99 days without a regeneration
  3. Cam Sense (Err 0): find what's slowing the piston
  4. Err 1 and UD: switch signals and drive resync
  5. Memory errors: soft reset vs Master Reset
  6. Most 5600SXT codes point to the piston, the meter or the settings
  7. FAQ

Fleck 5600SXT error codes at a glance

CodeNameWhat triggered itManual's recovery
Err 0Cam Sense ErrorValve drive took longer than 6 minutes to reach the next regeneration positionUnplug; check cam switches, motor, drive train and piston; plug in and watch
Err 1Cycle Step ErrorUnexpected cycle inputCheck cam switches; confirm valve and system type; run a manual regeneration
Err 2Regen FailureNo regeneration for over 99 days (7 if set to Day-of-Week)Manual regeneration; then check meter, capacity, day override
Err 3Memory ErrorControl board memory failureMaster Reset, reprogram, manual regeneration
UDUpper Drive SyncPower failure, install or programming changeRecovers automatically

Seeing Err 4, or an exclamation mark? Those aren't in the 5600SXT table. Retailers list them for Fleck's newer 5800 and 5810 controls, which use an optical sensor. Check the label on your powerhead before following a guide for another model, and see our Fleck 7000SXT error codes if yours is the larger valve.

Err 2 means 99 days without a regeneration

Flowchart for clearing Fleck 5600SXT Err 2: start a manual regeneration, run a tap, then check the meter cable or the Master Programming settings

Err 2 isn't a broken part. The control is telling you it hasn't regenerated in more than 99 days, which should never happen on a working softener. Clearing it is only half the job.

Clear it. With the timer in service, hold Extra Cycle for 5 seconds. The valve goes to backwash. Let it finish on its own, or press Extra Cycle to step through brine draw and slow rinse, rapid rinse, brine refill and back to service. Our Fleck 5600SXT manual regeneration guide covers both ways.

Find out why. On a metered system, run a softened tap and watch for the flow indicator on the display. No indicator means the control thinks no water has been used, so it never reaches capacity. Check the meter cable is seated at both the board and the meter, then see our meter not counting guide. Diagnostic mode (hold Up and Extra Cycle for 5 seconds) also shows the live flow rate as FR.

If the meter counts, check the settings in Master Programming: capacity, day override and meter type. On a Day-of-Week setup, make sure at least one day is ON. Our guide on how to program a Fleck 5600SXT walks through each screen.

Cam Sense (Err 0): find what's slowing the piston

Diagram of the four Fleck 5600SXT Err 0 checkpoints: motor, drive gears, cam and switches, and piston

Six minutes is a long time for a piston to move one position. Pentair's checklist, in a practical order:

  1. Unplug the unit.
  2. Cam switches. Make sure they're connected to the circuit board and their connectors are fully seated.
  3. Motor and drive train. Confirm the motor turns and the gears are intact and assembled correctly. A motor that hums but won't turn is covered in our motor not turning guide.
  4. The piston. It must travel freely. A piston dragging on worn seals, or packed with iron or sediment, is a classic Err 0 cause on well water. Put the softener in bypass and see our stuck piston guide.
  5. Plug back in and watch. The valve should move to its next position and stop. If Err 0 returns, Pentair says to contact technical support.

Err 1 and UD: switch signals and drive resync

Close-up of a control circuit board, where the Fleck 5600SXT cam switches plug in

Err 1 (Cycle Step) means the control got a cycle input it didn't expect. Check the cam switches and their wiring as for Err 0. Then confirm in Master Programming that the valve type and system type match your actual hardware; a mismatch is common after a board swap or a botched reprogram. Finish with a manual regeneration to prove every step completes.

UD (Upper Drive Sync) appears after a power failure, an install or a programming change while the drive resyncs. The manual lists no action: the valve recovers by itself. A flashing time of day after an outage is also normal; press any button to stop it.

Memory errors: soft reset vs Master Reset

Comparison of the Fleck 5600SXT Soft Reset (Extra Cycle plus Down for 25 seconds) and Master Reset (hold Extra Cycle while plugging in)

For Err 3, the manual's path is a Master Reset (hold Extra Cycle while plugging the unit in), then re-enter every setting in Master Programming and run a manual regeneration. A Soft Reset (hold Extra Cycle and Down for 25 seconds in service) is different: it returns settings to factory defaults but keeps the gallons remaining or days since regeneration.

Both wipe your programming, so photograph or write down hardness, capacity, regeneration time and cycle times first. If Err 3 returns after a clean reprogram, the board is failing.

Most 5600SXT codes point to the piston, the meter or the settings

Read Fleck 5600SXT error codes as a short list: Err 2 is almost always the meter or the programming, Err 0 and Err 1 are the switches, motor or piston, Err 3 is the board, and UD is nothing. A valve that keeps throwing Err 0 with a free-moving piston needs a motor, switches or board, all sold separately. On an old valve with worn seals too, a whole new head is often simpler: our best replacement control valves covers Fleck and Clack heads, and best Fleck water softeners covers complete systems.

FAQ

How do I clear Err 2 on a Fleck 5600SXT?

Hold the Extra Cycle button for 5 seconds to start a manual regeneration. The code resets once the regeneration runs. Then check that the meter registers flow and that the day override and capacity are set correctly, or it will come back.

What does Err 0 mean on a Fleck water softener?

On the 5600SXT, Err 0 is a Cam Sense Error: the drive took more than 6 minutes to reach the next regeneration position. Check the cam switch connections, the motor and gears, and whether the piston moves freely.

How do I reset a Fleck 5600SXT?

For a Soft Reset, hold Extra Cycle and Down for 25 seconds while in service. For a Master Reset, hold Extra Cycle while plugging the unit in. Both erase your settings, so note them first.

Will a power outage cause an error code on the 5600SXT?

Usually only UD or a flashing time of day. The control keeps time for at least 48 hours without power and stores its settings permanently. A regeneration missed during the outage runs at the next scheduled regeneration time.

Is Err 4 a Fleck 5600SXT error code?

No. Pentair's 5600SXT manual lists only Err 0 to Err 3 and UD. Err 4 is reported on Fleck 5800 and 5810 controls, so confirm your model before troubleshooting.